Locking Plate: Pre-galvanised strip
Wedge: Malleable iron, zinc plated.
Rod minimum 4.6 M6
Safe Working Load (FOS 3:1) Tensile / 1 Rod kN 1.0
Tightening Torque Nm 10
How to install
1. Pre-assemble the locking plate and wedge (flat surface up) onto the threaded rod and insert one side of the bracket into the re-entrant channel of the decking.
2. Click the other leg of the bracket into position inside the decking and slide the assembly to the desired position along the length of the re-entrant channel.
3. Push and turn the wedge clockwise until it locks into the channel walls.
4. Tighten the hexagon nut beneath the assembly.
Install the decking fixings after the concrete has been poured and has reached full strength.
If the decking profile is deformed or distorted, do not install the fixing.