Thread Diameter (mm) 10
Anchor Length (mm) 65
Hole Diameter (mm) 10
Maximum Fixture Thickness (mm) 8
Fixture Clearance Hole (mm) 12
Thread Length (mm) 25
Embedment Depth (mm) 45
Minimum Hole Depth (mm) 50
Structure Thickness (mm) 125
Installation Torque (Nm) 28
Installation Instructions
1. Position fixture and drill correct diameter hole to correct depth
2. Clean hole by brushing and blowing to remove all dust and drilling debris.
3. Insert assembled anchor through fixture into concrete.
4. Tighten with torque wrench to recommended torque.
Non-Cracked concrete
Performance Data (20/25 Concrete)
Thread Diameter (mm) 10
Characteristic Resistance (kN) Tensile 11.2
Characteristic Resistance (kN) Shear 14.5
Design Resistance (kN) Tensile 6.2
Design Resistance (kN) Shear 7.5
Recommended Resistance (kN) Tensile 4.4
Recommended Resistance (kN) Shear 5.4
Design Spacing (mm) Tensile & Shear 110
Design Edge Distance (mm) Tensile 55
Design Edge Resistance (mm) Shear 100
Shear Loads towards a free edge are for single anchors where Spacing > 3 x Edge Distance