Thread Diameter (mm) 8
Anchor Length (mm) 100
Hole Diameter (mm) 8
Maximum Fixture Thickness (mm) 55
Fixture Clearance Hole (mm) 9
Thread Length (mm) 70
Embedment Depth (mm) 35
Minimum Hole Depth (mm) 40
Structure Thickness (mm) 100
Installation Torque (Nm) 10
Installation Instructions
1. Position fixture and drill correct diameter hole to correct depth
2. Clean hole by brushing and blowing to remove all dust and drilling debris.
3. Insert assembled anchor through fixture into concrete.
4. Tighten with torque wrench to recommended torque.
Non-Cracked concrete
Performance Data (20/25 Concrete)
Thread Diameter (mm) 8
Characteristic Resistance (kN) Tensile 7.4
Characteristic Resistance (kN) Shear 9.2
Design Resistance (kN) Tensile 4.1
Design Resistance (kN) Shear 4.9
Recommended Resistance (kN) Tensile 2.9
Recommended Resistance (kN) Shear 3.5
Design Spacing (mm) Tensile & Shear 85
Design Edge Distance (mm) Tensile 45
Design Edge Resistance (mm) Shear 85
Shear Loads towards a free edge are for single anchors where Spacing > 3 x Edge Distance