Thread Diameter (mm) 6
Overall Length (mm) 100
Hole Diameter (mm) 12
Maximum Fixture Thickness (mm) 50
Fixture Clearance Hole (mm) 7
Embedment Depth (mm) 45
Minimum Hole Depth (mm) 50
Structure Thickness (mm) 100
Installation Torque (Nm) 6
Installation Instructions
1. Drill correct diameter hole to correct depth.
2. Clean hole by brushing and blowing to remove all dust and drilling debris.
3. Insert assembled anchor through fixture into concrete.
4. Attach fixture tighten with torque wrench to recommended torque.
Non-Cracked concrete
Performance Data (20/25 Concrete)
Thread Diameter (mm) 6
Characteristic Resistance (kN) Tensile 7.2
Characteristic Resistance (kN) Shear 8.0
Design Resistance (kN) Tensile 3.9
Design Resistance (kN) Shear 6.3
Recommended (kN) Tensile 2.8
Recommended (kN) Shear 4.5
Design Spacing (mm) Tensile & Shear 55
Design Edge Distance (mm) Tensile 55
Design Edge Distance (mm) Shear 65
Solid Brickwork
Performance Data (20 N/mm²)
Thread Diameter (mm) 6
Characteristic Resistance (kN) Tensile 5.2
Characteristic Resistance (kN) Shear 3.6
Design Resistance (kN) Tensile 2.5
Design Resistance (kN) Shear 1.7
Recommended Resistance (kN) Tensile 1.8
Recommended Resistance (kN) Shear 1.1
Recommended Spacing (mm) Tensile & Shear 55
Recommended Edge Distance (mm) Tensile 55
Recommended Edge Distance (mm) Shear 65
Tightening Torque (Nm) 5
Solid Concrete Blocks
Performance Data (7 N/mm²)
Thread Diameter (mm) 6
Characteristic Resistance (kN) Tensile 3.8
Characteristic Resistance (kN) Shear 2.1
Design Resistance (kN) Tensile 1.6
Design Resistance (kN) Shear 1.4
Recommended Resistance (kN) Tensile 1.1
Recommended Resistance (kN) Shear 1.0
Recommended Spacing (mm) Tensile & Shear 55
Recommended Edge Distance (mm) Tensile 55
Recommended Edge Distance (mm) Shear 65
Tightening Torque (Nm) 5
Due to the variable nature of bricks and concrete blocks these figures are for guidance only