M12 ETA Approved Drop In Anchor
Thread Diameter (mm) 12
Anchor Length (mm) 50
Hole Diameter (mm) 15
Fixture Clearance Hole (mm) 14
Internal Thread Length (mm) 18
Embedment Depth (mm) 50
Minimum Hole Depth (mm) 50
Minimum Structure Thickness (mm) 140
Maximum Installation Torque (Nm) 35
Cracked and Non-cracked concrete (Multiple use for non-structural applications)
Performance Data (C20/25 Concrete)
Thread Diameter (mm) 12
Characteristic Resistance (kN) Load in any direction 6.0
Design Resistance (kN) Load in any direction 3.33
Approved Resistance (kN) Load in any direction 2.37
Spacing (mm) Tensile & Shear 150
Edge Distance (mm) Tensile & Shear 165
Non-Cracked concrete
Performance Data (C20/25 Concrete)
Thread Diameter (mm) 12
Characteristic Resistance (kN) Tensile 17.8
Characteristic Resistance (kN) Shear 16.8
Design Resistance (kN) Tensile 11.9
Design Resistance (kN) Shear 10.06
Approved Resistance (kN) Tensile 8.5
Approved Resistance (kN) Shear 7.18
Spacing (mm) Tensile & Shear 150
Edge Distance (mm) Tensile 165
Edge Distance (mm) Shear 165