Thread Diameter (mm) 10
Length Under Head (mm) 70
Hole Diameter (mm) 16
Maximum Fixture Thickness (mm) 8
Fixture Clearance Hole (mm) 12
Embedment Depth (mm) 60
Minimum Hole Depth (mm) 65
Structure Thickness (mm) 120
Installation Torque (Nm) 27
Installation Instructions
1. Drill correct diameter hole to correct depth.
2. Clean hole by brushing and blowing to remove all dust and drilling debris.
3. Insert assembled anchor through fixture into concrete.
4. Position fixture, Insert bolt, Tighten with torque wrench to recommended torque.
Non-Cracked concrete
Performance Data (20/25 Concrete)
Thread Diameter (mm) 10
Characteristic Resistance (kN) Tensile 20.3
Characteristic Resistance (kN) Shear 17.8
Design Resistance (kN) Tensile 11.2
Design Resistance (kN) Shear 11.9
Recommended (kN) Tensile 8.0
Recommended (kN) Shear 8.5
Design Spacing (mm) Tensile & Shear 180
Design Edge Distance (mm) Tensile 95
Design Edge Distance (mm) Shear 120
Solid Brickwork
Performance Data (20N/mm²)
Thread Diameter (mm) 10
Characteristic Resistance (kN) Tensile 8.4
Characteristic Resistance (kN) Shear 11.4
Design Resistance (kN) Tensile 4.0
Design Resistance (kN) Shear 2.1
Recommended Resistance (kN) Tensile 2.9
Recommended Resistance (kN) Shear 5.4
Recommended Spacing (mm) Tensile & Shear 180
Recommended Edge Distance (mm) Tensile 95
Recommended Edge Distance (mm) Shear 120
Tightening Torque (Nm) 22
Solid Concrete Blocks
Performance Data (7N/mm²)
Thread Diameter (mm) 10
Characteristic Resistance (kN) Tensile 10.7
Characteristic Resistance (kN) Shear 6.7
Design Resistance (kN) Tensile 4.4
Design Resistance (kN) Shear 4.4
Recommended Resistance (kN) Tensile 3.1
Recommended Resistance (kN) Shear 3.1
Recommended Spacing (mm) Tensile & Shear 180
Recommended Edge Distance (mm) Tensile 95
Recommended Edge Distance (mm) Shear 120
Tightening Torque (Nm) 22
Due to the variable nature of bricks and concrete blocks these figures are for guidance only.