Locking Plate: Pre-galvanised strip
Wedge: Malleable iron, zinc plated.
Rod minimum 4.6 M6
Safe Working Load (FOS 3:1) Tensile / 1 Rod kN 1.0
Tightening Torque Nm 10
How to install
1. Pre-assemble the locking plate and wedge (flat surface up) onto the threaded rod.
2. Insert the wedge into the re-entrant channel of the decking and rotate 90°.
3. Slide the plate up the threaded rod, over the wedge, to lock it in position into the channel.
4. Tighten the locknut beneath the plate to hold the assembly in position.
Install the decking fixings after the concrete has been poured and has reached full strength.
If the decking profile is deformed or distorted, do not install the fixing.