Thread Diameter (mm) 10
Drill Hole Diameter (mm) 16
Clearance Hole Diameter (mm) 12
Minimum Hole Depth (mm) 65
Minimum Embedment Depth (mm) 60
Recommended Tightening Torque (Nm) 27
Recommended Load in any Direction
Hook Bolt (kN) 2.5
Minimum Spacing (mm) 180
Minimum Edge Distance (mm) 90
Loads are for 30N/mm² concrete
The Hook and Eye Shield Anchors are suitable for use for static loads only. They cannot be used as lifting points or for use with safety restraint harnesses.
Installation Instructions
1. Drill correct diameter hole to minimum recommended depth.
2. Clean hole by brushing and blowing to remove drilling debris and dust.
3. Insert shield with hook or eye assembled, into hole.
4. Tighten nut to Recommended Torque.